Which Premises in Hong Kong Need Fire Buckets or Sand Buckets? A Guide to Legislation, Licence Conditions, FSD Requirements and Assessing Each Type of Premises
"Does my shop need a sand bucket?" is a common question from owners and operators. The answer is rarely a simple yes or no. Hong Kong has no single list setting out "which premises must provide sand buckets". Instead, sand bucket requirements are spread across individual pieces of legislation, dangerous goods licence conditions, the written requirements issued by the Fire Services Department (FSD) for individual premises, and building management or works contract requirements. This guide sets out where sand bucket requirements come from and analyses each type of premises in turn, to help you decide whether your premises needs one and how to handle it.
Quick answer: Premises that need sand buckets mostly involve the storage or use of flammable liquids, such as dangerous goods stores, emergency generator rooms, fuel tank rooms, petrol stations, construction sites, garages and some workshops. Whether one must be provided, how many and where depends on the applicable legislation, dangerous goods licence conditions or the FSD's written requirements for the premises. Some legislation contains express requirements: for example, the Factories and Industrial Undertakings (Work in Compressed Air) Regulations require the relevant facilities to be provided with 2 buckets of dry sand. Premises without an express requirement but with flammable liquid risks can also provide sand buckets on the basis of a risk assessment.
Contents
- Five sources of sand bucket requirements
- Express requirements in legislation
- Dangerous goods premises
- Generator rooms and fuel tank rooms
- Petrol stations and car parks
- Construction sites
- Garages, workshops and industrial units
- Laboratories and schools
- Restaurants, shops and other premises
- Summary by premises type
- Decision process
- Frequently asked questions
1. Five Sources of Sand Bucket Requirements
| Source | Examples | Binding force |
|---|---|---|
| 1. Express provisions in legislation | Some industrial safety regulations expressly require dry sand to be provided | Statutory requirement |
| 2. Dangerous goods licence conditions | Storing dangerous goods above the exempt quantity requires an FSD licence and compliance with its conditions | Licence conditions, binding |
| 3. FSD written requirements for individual premises | Fire safety requirements issued by the FSD when licensed premises apply for a licence | Licensing conditions |
| 4. Building fire service installation design | Portable appliances specified in the building design and fire service installation plans | Must be retained and maintained according to the approved design |
| 5. Contract, building management or insurance requirements | Works contracts, management office rules, insurer requirements | Contractual or management requirement |
Once a sand bucket has been provided in the premises, whatever the source of the requirement, it should be kept to the specification in the FSD code: fitted with a lid, a capacity of not less than 9 litres, red with Chinese and English labels, dry sand only, filled to at least 80%, and inspected every 12 months or after use. See What Are Fire Buckets and Sand Buckets?.
2. Express Requirements in Legislation
Some Hong Kong legislation expressly requires dry sand. For example, the Factories and Industrial Undertakings (Work in Compressed Air) Regulations (Cap. 59M), in listing the items a medical lock must be equipped with, include "2 buckets of dry sand". Provisions of this kind apply to specific working environments and are not widely applicable, but they show that sand buckets are a statutory requirement in some situations.
Other legislation does not mention sand buckets directly but requires any fire-fighting appliances provided to be kept in good condition. For example, section 54 of the Construction Sites (Safety) Regulations (Cap. 59I) requires the contractor responsible for a construction site to keep all means of escape and fire-fighting appliances provided on the site in good condition and free from obstruction. Section 53 also gives the authority power to prohibit smoking on sites where flammable liquids or substances involving a fire risk are used. In other words, if a site has provided sand buckets, they must be kept in good condition.
3. Dangerous Goods Premises
Under the Dangerous Goods Ordinance (Cap. 295), anyone who manufactures dangerous goods, or stores, conveys or uses dangerous goods above the exempt quantity, must hold a licence issued by the FSD under that Ordinance. Flammable liquids (Category 3 dangerous goods) are the most common category, such as paints, paint thinners, solvents, kerosene and diesel.
Dangerous Goods Premises and Sand Buckets
- Licensed dangerous goods stores: the FSD sets fire safety requirements according to the type and quantity of dangerous goods and the conditions of the premises, and the type and number of fire-fighting appliances follow the licence conditions.
- Storage below the exempt quantity: a licence may not be required, but there is still a fire risk. If flammable liquids are stored, a sand bucket can help contain leaks and put out small fires at floor level.
- Dangerous goods compatibility: some dangerous goods are not suitable for treatment with sand or other methods, so fire-fighting appliances should be chosen according to the safety data for the dangerous goods and FSD requirements.
The FSD runs a dedicated dangerous goods website where you can look up the category, exempt quantity and compatibility of individual dangerous goods. If you are unsure whether your storage exceeds the exempt quantity, check first and then decide whether a licence is needed.
4. Generator Rooms and Fuel Tank Rooms
Emergency generator rooms and fuel tank rooms in buildings are the most common places for sand buckets. Generators run on diesel, and fuel may leak during refuelling, maintenance and day-to-day operation. Fuel tank rooms store fuel oil for long periods.
Key Points
- Fire service installations in buildings are generally provided according to the approved design. If sand buckets are part of the original design, they must be retained and maintained to specification.
- Sand buckets are best placed near the plant room entrance, so staff can reach them as soon as they enter.
- Plant rooms run hot, so metal sand buckets are preferable.
- Plant rooms may have condensation or leaks, so check whether the sand has become damp.
- Sand buckets are best provided together with extinguishers suitable for electrical and flammable liquid fires.
Building management offices should include plant room sand buckets in the annual fire service installation inspection; see our Complete Guide to Fire System Maintenance and FS251 Annual Inspection.
5. Petrol Stations and Car Parks
Petrol Stations
Petrol stations handle large volumes of petrol and diesel and are high-risk premises. Their fire safety requirements are set by the relevant departments according to the conditions of the premises. Sand buckets are among the fire-fighting appliances commonly found at petrol stations, mainly for containing and dealing with fuel spilled during refuelling.
Car Parks
Vehicles in car parks may leak petrol, diesel or engine oil. Many car parks provide sand buckets for use together with fire extinguishers. Fire service installations in car parks are generally provided according to the building design and FSD requirements. Managers should confirm whether existing sand buckets are part of the original design or were added later, and maintain all of them to specification.
6. Construction Sites
Common fire risks on construction sites include:
- Fuel for fuel-powered machinery and generators
- Paints, solvents and adhesives
- Hot work such as welding and cutting
- Timber, packaging materials and waste
Recommendations for Construction Sites
- Provide sand buckets near fuel storage and refuelling locations to help deal with leaks.
- Hot work locations generally need fire-fighting appliances; provide fire extinguishers and sand buckets according to the nature of the work.
- Sites are mostly outdoors, so keep sand buckets in covered locations with their lids on to prevent rain from wetting the sand.
- Under the Construction Sites (Safety) Regulations, fire-fighting appliances provided must be kept in good condition and free from obstruction.
- Specific site requirements should also follow the works contract, safety plan and the contractor's safety management system.
7. Garages, Workshops and Industrial Units
Garages and Vehicle Repair Workshops
Garages handle engine oil, petrol, brake fluid and solvents, and oil on the floor is common, making them a typical place for sand buckets. Besides fire-fighting, sand can also be used to soak up small amounts of oil day to day. Note, however, that sand for routine cleaning should not come from the fire sand bucket, which must stay full of dry sand ready for emergencies.
Workshops and Industrial Units
Industrial units are often used for printing, spray painting, furniture making, repair workshops and similar purposes, and may use flammable solvents and paints. These premises should:
- Confirm whether the quantity of flammable liquids stored exceeds the dangerous goods exempt quantity
- If a licence is needed, provide fire-fighting appliances according to the licence conditions
- If no licence is needed, provide sand buckets and suitable extinguishers near flammable liquids according to the risk
- Avoid stockpiling large quantities of flammable liquids in the unit
8. Laboratories and Schools
Laboratories in schools, universities and research institutions use flammable chemicals, and sand buckets are a common supplementary appliance, usually provided together with fire blankets and CO2 extinguishers. Note that different chemicals require different fire-fighting methods, and some are unsuitable for treatment with sand or water. Laboratories should choose appropriate fire-fighting appliances and procedures according to the safety data for the chemicals they use.
9. Restaurants, Shops and Other Premises
Restaurants
Portable fire-fighting equipment in restaurants generally includes CO2 extinguishers, water extinguishers and fire blankets, according to the FSD's written requirements. Wok or pan fires in kitchens should be dealt with using a fire blanket or a suitable extinguisher; sand is not recommended. Sand buckets are not a common requirement for ordinary restaurants unless the premises also stores flammable liquids. For restaurant requirements, see Fire Retardant Paint and False Ceiling Requirements for Restaurants.
Ordinary Shops and Offices
The main risks in ordinary retail shops and offices are paper, fabric and electrical equipment, with little involvement of flammable liquids. They usually rely mainly on fire extinguishers and do not need sand buckets. However, if a shop sells or stores paints, solvents or fuel, it should assess whether one is needed.
Homes
Ordinary homes do not need sand buckets. The FSD suggests dry powder extinguishers for home use, and a fire blanket can be added for the kitchen. For a comparison of appliances, see Fire Buckets, Fire Extinguishers or Fire Blankets: How to Choose?.
Vessels, Piers and Outdoor Events
Piers and vessels involving fuel supply, and outdoor events using generators, also commonly provide sand buckets. Specific requirements follow the rules of the relevant departments, venues or event organisers.
10. Summary by Premises Type
| Premises | Are sand buckets commonly provided? | Source of requirement |
|---|---|---|
| Licensed dangerous goods stores | Common | Dangerous goods licence conditions |
| Emergency generator rooms | Common | Building fire service installation design, management requirements |
| Fuel tank rooms | Common | Building fire service installation design, management requirements |
| Petrol stations | Common | Requirements of the relevant departments |
| Car parks | Common | Building fire service installation design, management requirements |
| Construction sites | Common | Works contracts, safety management; those provided must be kept in good condition |
| Garages, repair workshops | Common | Risk assessment, licence conditions (if applicable) |
| Workshops using solvents | Depends on circumstances | Dangerous goods licence (if above the exempt quantity), risk assessment |
| Laboratories | Depends on chemicals | Institutional safety rules |
| Compressed air work facilities | Expressly required by law | Cap. 59M |
| Restaurants | Generally not needed | Follow the FSD's written requirements |
| Ordinary shops, offices | Generally not needed | Unless flammable liquids are involved |
| Homes | Generally not needed | Dry powder extinguishers and fire blankets recommended |
The table reflects general situations. Individual premises follow the applicable legislation, licence conditions and written requirements.
11. Decision Process
- Are there flammable liquids in the premises? If not, a sand bucket is generally not needed; if so, go to the next step.
- Does the quantity stored exceed the dangerous goods exempt quantity? If so, a dangerous goods licence is required, and fire-fighting appliances must be provided according to the licence conditions.
- Is the premises licensed? If so, check the FSD's written requirements for the premises.
- Did the building's original design include sand buckets? If so, they must be retained and maintained to specification.
- Are there contract, management office or insurance requirements? If so, provide sand buckets as required.
- None of the above contains an express requirement? You can still provide sand buckets near flammable liquids on the basis of a risk assessment, maintaining them all to the FSD specification.
Numbers and Locations
Where the requirements specify numbers and locations, follow them. Where they do not, the following principles apply:
- At least one near each main location where flammable liquids are used or stored
- Placed at an entrance or on the escape side, easy to see and reach
- Kept together with suitable fire extinguishers
- Not obstructing walkways or other fire service installations
12. Frequently Asked Questions
Is there a law in Hong Kong listing which premises must have sand buckets?
Hong Kong has no single list of all premises that must provide sand buckets. Sand bucket requirements are spread across individual pieces of legislation, dangerous goods licence conditions, the FSD's written requirements for individual premises, building fire service installation designs and so on.
Does any legislation expressly require sand buckets?
Yes. For example, the Factories and Industrial Undertakings (Work in Compressed Air) Regulations (Cap. 59M) require the relevant facilities to be provided with 2 buckets of dry sand.
Must a generator room have a sand bucket?
Generator rooms are among the most common places for sand buckets. If a sand bucket is part of the building's fire service installation design, it must be retained and maintained to specification. Specific requirements follow the building's approved design and FSD requirements.
Does an industrial unit storing paint and paint thinner need a sand bucket?
First confirm whether the quantity stored exceeds the dangerous goods exempt quantity. If it does, a dangerous goods licence is required and fire-fighting appliances must be provided according to its conditions. If not, it is still advisable to provide a sand bucket and suitable extinguishers near the storage location.
Do construction sites need sand buckets?
Construction sites often involve fuel, solvents and hot work, and generally provide sand buckets and fire extinguishers at the relevant locations. The Construction Sites (Safety) Regulations require fire-fighting appliances provided to be kept in good condition and free from obstruction, and specific requirements should also follow the works contract and safety management system.
Do car parks need sand buckets?
Many car parks provide sand buckets to deal with fuel leaking from vehicles. Specific requirements follow the building's fire service installation design and FSD requirements, and any sand buckets provided must be maintained to specification.
Do restaurants need sand buckets?
Portable fire-fighting equipment in ordinary restaurants is mainly CO2 extinguishers, water extinguishers and fire blankets, according to the FSD's written requirements. Sand is not recommended for wok or pan fires in kitchens.
Do homes need sand buckets?
Ordinary homes do not need sand buckets. The FSD suggests dry powder extinguishers for home use, and a fire blanket can be added for the kitchen.
Do sand buckets I add myself also need to meet the specification?
It is advisable to provide and maintain all sand buckets to the FSD code specification, including a lid, a capacity of not less than 9 litres, red with Chinese and English labels, dry sand only and filled to at least 80%, so that they work in an emergency.
Who can I ask if I am unsure whether I need a sand bucket?
Check the FSD's written requirements or licence conditions for the premises, or ask a Registered Fire Service Installation Contractor to assess the risks in your premises.
Sand Bucket Assessment and Supply
Grand United Eng., Co. is a Registered Fire Service Installation Contractor in Hong Kong. We can assess flammable liquid risks for generator rooms, fuel tank rooms, car parks, workshops, construction sites and all types of premises, advise on the provision of sand buckets and fire-fighting appliances, supply sand buckets that meet the specification, and arrange inspections and the FS251. When you contact us, please provide the premises type, the types and quantities of flammable liquids, site photos and any relevant requirements. You can also browse our Fire Safety Products, Fire Engineering Services and Service Coverage.
Enquire about sand bucket provision, or call 2667 7701.