Fire Safety Products

We supply and install a variety of fire safety products that meet the criteria recognized by Hong Kong Fire Services Department, covering hand-held fire extinguishing equipment, evacuation lighting and instructions, water fire suppression systems and detection and alarm devices. The installation, maintenance, repair and inspection of all fire service installations in the premises shall be at the appropriate levelRegistered Fire Service Installation ContractorImplementation and possible issuance and electronic submission after completionFS251 Certificate。 More detailed specifications can be consultedProduct catalogue guideNeed for " request for electricity 2667 7701 or WhatsApp 90114454。

Product fairs

fire safety products

The following products may be supplied separately.fire protection system installed、fire equipment maintenanceand annual inspection arrangements.

Dry powder fire extinguisher plutonium applicable to A, B and C types of fire

Dry powder fire extinguisher

The broadest range of hand-held fire extinguisher applies to categories A (wood, paper, plumbing), B (flammable liquid and flammable gases) and C (electric devices) fire, which are the most common types of shop, office, industrial building and vehicles.

Note: More residues of post-spray powder are needed for clean-up; Long-outstanding potential dry powder packs are subject to annual inspection. Special metal fire requires the use of special fire extinguishers, which cannot be assumed to apply in general dry powder.

Category ACategory BCategory CLevel 3
Water agent fire extinguisher plutonium only applies to category A fire

Water agent fire extinguisher

Water-clearing fire extinguisher is used to save wood in combustion, cotton textiles and paper type A fire, often in old buildings and storage sites.

Note: Cables are used to inculcate electrical equipment, flammable liquids or metals in combustion, clean water-up and spread the oil fire.

Category ALevel 3
foam fire extinguisher ' s bubble applicable to A, B types of fire

foam fire extinguisher

Insulated air with foam cover is applicable to categories A and B fire, particularly flammable liquids in combustion, which are often found at work sites involving oil or solvents.

Note: The foam is a guiding body, and it is used to extinguish electrical equipment in combustion.

Category ACategory BLevel 3
Carbon dioxide fire extinguisher plutonium applicable to categories B, C

carbon dioxide fire extinguisher

(b) Applies electrical equipment in combustion, flammable liquids, sophisticated instruments, important documents or fire occurring in closed areas; The fires will not be residueed and suitable for server room, electrical appliances and the restaurants area.

Note: Carbon dioxide can be an abhorrent, and after fire extinguisher it should go to the open space; Incendiary combustion of deep layers such as paper plumbers is more difficult to completely extinct.

Category BCategory CLevel 3
fire blanket bathrooms and initial small fires at laboratories

fire blanket

The isolation of the air by means of coverage is a permanent equipment for food premises and kitchens applicable to flammable liquids in combustion, as well as small fires occurring in kitchens or laboratories.

Note: The use shall be followed by checking whether or not the damage or carbonization; The location should be close to the lithium but not directly polluted by oil smoke.

Application of kitchensLevel 3
exit sign instruction to confirm export routes

exit sign

Fixed-launching plates that direct an approved export route, the maintenance of a backup battery at the time of the suspension, are the most basic guiding devices for moving the flame.

Keys for maintenance: whether the direction is correct, whether it has been branded, astronomical or dressed, and whether the batteries can still be maintained at the prescribed time.

Evacuation instructions
Emergency lighting for emergency lighting

Emergency lighting

Installation is in the building to provide sufficient backup lighting as a matter of urgency, ensuring that fire corridors, stairs and exports continue to be fitted for evacuation in the event of power cuts.

Maintenance keys: periodic discharge testing, battery life, fluid cover and walking of the flame receptacle; The ageing of batteries is one of the most common deficiencies in annual inspection.

emergency lighting
fire hose reel and fire safety stoves

fire safety . / ⁇ system

In the building, the water column can be fired at any time into any part of the building in order to save the fire. fire hose reel was used for early rescue of the person present, while fire safety was provided by fire safety officers to access water.

Keys for maintenance: Water pressure and water testing, plumbing and spraying conditions, the availability of filters, valves and markings, and non-disrupted by impurities. Beneficiary of level 2.

Water fire extinguishingLevel 2
fire Detection system pyroly detecting thermal power of cigarettes

fire Detection System

Systems for automatic detection and alarming of cigarettes, heat, combustion-generated substances or flames, consisting of detectors, control mainframes, sound clocks and back-up power sources, can be linked to winds, gates or gaseous fire suppression system.

Selective elements: corridors and office smoke detector; Heat detector should be used to reduce miscalculations, such as kitchens, car rooms, where it is easy to generate gas or oil smoke. Under level 1 contractor.

Automatic detectionLevel 1
Hand-held fire alarm system breaking glass cartridge launch

Hand-held fire alarm system

When fire occurs, glass can be broken into the start alarms, other persons within the dispersal site and associated devices (e.g. fire pumps, if any).

(c) Keys for maintenance: whether the position is easy to approach, whether or not the former are blocked by the goods, brake tests and repositions, and whether the marking is clear. Under level 1 contractor.

People ' s hands-onLevel 1
automatic sprinkler system  ⁇ sensure automatic water

sprinkler system

When fire occurs, sprinkler head feels that designated temperatures will automatically pump water and launch water flush alarms, while local control of the spread of fire is a core firefighting system for large businessfields, industrial building and warehouses.

(c) Maintenance keys: sprinkler head shall not be wheeled, branded, mounted or tubed; The high level of dumping of goods shall not affect the water; Anyone affected by collision or covered by the paint shall be replaced. Beneficiary of level 2.

Water fire extinguishingLevel 2

Illustrative amendment: The fire detection system on this page means an automatic detector, a hand-written fire alarm system masks the alarm device that is activated by shredding glass, with different functions but usually shared a set of control mainframes and clocks.

Selection guide

Selection of fire extinguisher by type of fire

Staggered fire extinguisher is not only ineffective, but it is more likely that the fire will be extended or triggered. Hong Kong ' s commonly used fire is classified as A (general flammable items such as timber, paper, plumbing), B (flammable liquids and flammable gases), C (electric devices).

fire extinguisher type compared with the applicable fire category
TypeCategory of applicationTypical sitesRestrictions on use
Dry powderA、B、Cshop , office, industrial building , warehouse, vehiclesResidue powder need to be cleared; Dry powder potential block
carbon dioxideB、Cserver room, distribution of electricity, data centre, precision instrument area(a) The risk of sleeping in closed space; Deep combustion is more difficult to extinguish.
FoamsA、BOil stores, workshops, plantElectricity, not available for use in electrical appliances
Water cleaning (water agent)Limited APaper Warehousing, old building public partIn no way can be used for fuel or electrical fire
category wet chemicalFuel for feeding (European standard, category F, United States standard K)Commercial kitchens, food premisesThe use of the automatic fire-fighting system and fire blanket should be complemented by kitchens

Elements to be considered in configuration

  • Risk source location: appliances, electrical appliances, oil storage areas should be prioritized for suitable types.
  • Distance: Users should not need to wear the firefield in order to obtain fire extinguisher.
  • User capacity: The weight and operational difficulties need to be matched with on-site personnel, such as residential buildings and schools.
  • Environmental conditions: Indoor, wet or high temperatures can speed up corrosion and require more frequent visual inspection.
  • Markings and walls: positioning, marking and maintaining the front without any resistance.

Frigour fire extinguisher used four steps: ra, fingerprints, pressure, cleaning

  1. La : Confirmation of the type, positioned on the wind and elevated security needles.
  2. Refers to: shackling or tubes, to the bottom of the fire source.
  3. Pressure: Releasing fire extinguishers under pressure and maintaining a safe distance.
  4. Scanning: Some sweeping burns until they are completely extinguished.

Sufficient rescue is sought only when the fires remain at an early stage, with a clear regression and their own security. Smoking proliferation or spread of fires should be immediately withdrawn, closed and hand-held fire alarms activated and electrical 999.

Additional classification notes and chartsfire safety: fire classification and fire extinguisher selectionandfire safety and teaching。

Handheld equipment maintenance

fire extinguisher inspection, fire extinguisher annual inspection and fire extinguisher for medication

According to the Fire Services Department ' s Code of Conduct for Inspection, Testing and Maintenance of Minimum Fire Service Facilities and Equipment, such fire extinguisher should be tested every 12 months, while all fire extinguisher must undergo a stress test within five years. Hand-held equipment falls within the scope of work of level 3 registered fire service installation contractor (RC3 contractor).

Annual inspection project

  • (a) The pressure sheet is to mean whether it is normal; There is no corrosion, trap or leakage.
  • (b) The completeness of safety syringes, seals and labels; (b) Whether the last inspection date expires.
  • No spraying, spraying and chicken tubes are old, fracture or inertia.
  • The status of the pharmacies (whether the dry powder) and the total weight are not marked.
  • The walls, the hanging heights, the instructions are sufficient and whether access routes are blocked by the goods.
  • The type corresponds to the risk on-site (e.g., pumping, electricity ward, different storage requirements).

Economies, pressure tests and replacements respectively

Fire Extinguisher Servicing
Ecstasy failures, closures, under pressure or outdated use, recharged adhesive fire extinguishers and reprofiled lead.
Pressure test
(a) To recognize that the structure of the body remains safe and that it is subject to a code of conduct within five years; This is done in parallel with each annual inspection and cannot be replaced by another.
Replacement
(a) Being seriously corroborated, parked or repair costs are more reasonable when they are close to the new purchase price; Old plutonium should be properly handled by the contractor.

It is common misunderstanding that iodine has not been used to justify it. Pharmacies and pressures change over time, while annual inspection records and FS251 also need to reflect the condition of hand-held equipment, so that even when never used, it is subject to annual inspections.

Evacuation light

emergency lighting and export instruction products

Emergency lighting and emergency lighting systems

The power park or fire appliances provide backup lighting that allows users to identify the flame corridor and stairs. The choice of the product will need to consider the location of installation (strand, wall, water-proof), exposure and batteries. The focus is on the lifetime of electrical discharge testing and batteries, as well as whether there is a lighting damp after refurbishment.

exit sign and export sign

Fixed-launching signs to instruct export routes need to be ensured in the right direction and within a line of view. The most common substantive problems are new plates, shrimps or daylight changes to direct lights.fire protection system changeProjects that must be dealt with together.

Frequent replacement time

  • Electricity testing cannot be maintained for a specified time, indicating that the batteries have been ageing.
  • The lamp or LED tumours are markedly decayed, saturated or indecent.
  • The effects of casualty tetanus, variants and decays are visual.
  • The refurbishing position is no longer in line with the evacuation route.

Water fire extinguishing

Products associated with the water fire suppression system

automatic sprinkler system with sprinkler head

The head of sprinkler is in different modes of temperature with a sensory element, and the installation must be matched to the flower form and space altitude. The most common problem of maintenance is clouds: controversy changes, billboards, cranes or wind tubes may cause inadequate water coverage. sprinkler head is to be replaced by a collision change, covered by paint or oil effluent, or if there are indications of leakage, and is constructed by a registered contractor at level 2.

fire hose reel, fire safety pumps and accessories

These include tubes, spraying, wheelchairs, fumigations and cadmium. The inspection focused on the availability of water pressure and fluctuation, whether the tubes were old fractured, and whether the doors and markings were complete. Precursors are not allowed to load the impurities, which is one of the most frequently identified issues in the inspection.

fire pump and pressure

Key equipment to maintain system water pressure. Maintenance includes operational tests, pressure and flow inspections, control of the state of aluminium and power supply, leakage and anomalies, as well as ventilation, drainage and access.

Water system and water pump system

For special risk locations or segregated protections, the spray cleanness and control state shall be checked with the original design intent.

Structural and change arrangements at the system level can be foundFire engineeringReference to individual casesProjects。

Detection alarm

Detection and alarm products

smoke detector

Early burning is more sensitive and applies to corridors, offices, rooms and guest houses. Common problems are stokes, refurbishing dairy, wet turbines and departing from the original design coverage after astronomy change.

heat detector

Temperature is triggered and applies to the location where bathrooms, cars, kitchens, etc. generate gas or oil smoke, smoking detector prone to error.

fire alarm bell and clock

The examination focused on audio and coverage, particularly in room, insane rooms, more garment rooms and noise rooms. Additional clocks are often required after the break-up.

Hand-held fire alarms (shrap glass devices)

It is necessary to be located in a position that is easily accessible, and the former shall not be blocked by the goods or displays and shall be tested and re-located on a regular basis.

Control of mainframe and back-up power supply

(c) To check the normality of malfunctioning lights and incident records, road completeness, condition of backup batteries and links with wind machines, gate bans, gaseous fire suppression system.

The erroneous causes are mostly concentrated in four: accumulating and refurbishing, wet gas and ammonia, ageing of the route and unloading of detectors to inappropriate positions. It is more effective to re-establish the mainframe than it has repeatedly, by identifying causes and adjusting the selection or location.

Schedule

The timing of product inspection and replacement

Frequency of inspections and common reasons for replacement of various types of fire safety products
ProductsFrequency of statutory or recommendationReasons for frequent replacement or remedial work
Shand fire extinguisherEach 12-month test; 5 Pressure test for yearPharmaceutical block or lapse, under pressure, sealed lead tetanus, corrosion of copper
fire blanketComplementing annual inspectionsDetermination, carbonization and severe oil pollution
emergency lighting lampAnnual inspections include plating tests; Recommendation for quarterlyBattery ageing, fluorescent lamps and inadequate lighting
exit signAnnual inspections; Recommendation monthlyOld batteries, surviving crusts virginity, bedding and error of direction
Smoking and heat detectorAnnual inspection and functional testingStorage, oil flue pollution, erroneous frequencies, location deviation coverage
fire alarm bell with hand alert pointsAnnual inspection and rolling testInadequate number of noises, lack of hearing in individual rooms and deactivation
sprinkler headAnnual inspections; Changes to be reassessedLeaching, deformation, paint cover, leakage
fire hose reel and accessoriesAnnual inspection and water pressure testingInsufficient water pressure, old piping, fluctuation of copper cards, leakage
fire pump and pressureAnnual inspections; Recommendation for quarterlyWater leakage, noise, pressure anomalies and control latrines closed
gaseous fire suppression system steel bottlesAnnual inspection pressure or weightInconsistency of pressure or weight, problems of pipelines and spraying, failure to act together

Full annual inspection process, remedial work and certification arrangements are availablefire protection system maintenance and annual inspection; Fully observed compliance timelinesfire safety information: annual compliance calendar。

Information on procurement

Procurement and installation matters

I. Construction of a registered contractor at the corresponding level

In accordance with the fire safety (instructions and equipment) Ordinance (chap. 95B), non-registered contractors are not allowed to install, maintain, repair or inspect fire service installations or equipment at any place. Level 1 counter-detection and alarm devices; Level 2 corresponds to pipe and other electrical installations for the transmission of water or other fire extinguishers (except hand-held equipment); Level 3 counterpart equipment. Self-purchasing and installation is not only likely to be inconsistent with the requirements of legislation, but also difficult to issue certificates reflecting an effective state at the time of the annual inspection. Level comparisonfire safety knowledge: RC1/RC2/RC3 division of labour。

II. Products subject to accreditation criteria

The minimum configuration, inspection, testing and maintenance of fire service installations and equipment is based on the Fire Services Department ' s Code of Conduct and Inspection, Testing and Maintenance of Equipment. The type and specifications of the product should be recognized at the time of procurement as being consistent with the applicable requirements of the service, rather than comparing prices only.

III. Certified FS251 after completion

The registered fire service installation contractor is required to send FS251 Certificate of Fire Service Installations and Equipment to the person entrusted after completion of the installation, maintenance, repair or inspection, and to send a copy to the Fire Services Department within 14 days of completion. Since 1 July 2026, the certificate has been fully resubmitted electronically and an electronic certificate with a two-dimensional code is produced, with copies archived by the owner.

IV. " Separate products, working hours and follow-up

  • Cost of products: type, specifications and quantity.
  • Installation hours: there is a need for walking, drilling, high-altitude operations and non-commercial construction.
  • Follow-up arrangements: Are the first annual inspection, conversion or replacement of batteries included.
  • Old dispositions: old fire extinguisher ' s treatment with the layout.

Integrating product replacement with annual inspection arrangements, usually reduces the number of attendance and overallAnnual fire safety inspection fees。 Requestfire engineering "It was suggested that a list of devices be provided or the last FS251.

FAQs

fire safety products and common problems

How can fire extinguisher be selected according to the type of fire?

A, B, C for dry powder; Category B, C; Category A, B of the foams; (a) A water-cleaning limit; Commercial kitchen fuels are suitable for the wet chemical category (Eurostat, category F, United States standard, category K). See tableSelection by type of fire。

How long did fire extinguisher examine? Stress tests are to be carried out on several occasions?

Every 12 months should be tested and all fire extinguisher must undergo a pressure test within five years. For further detailsfire extinguisher inspection and exchange of medicines。

What are the options for switching and whole replacement?

(b) Ineffective, blocked, under pressure or negotiable drugs used; It is appropriate that the costs of a severe corrosion change, spare parts cut off or repairs close to the new purchase price.

Who can check fire extinguisher?

(b) The portable equipment is covered by the contractor for a registered fire service installation at level 3; Under Chapter 95B, non-registered contractor shall not be permitted to install, maintain, repair or inspect fire service installations or equipment within the premises.

What are the detection systems separate from manual fire alarm system?

The former automatically detects and alerts pyrotechnics, thermal power, substances or flames arising from combustion; The latter needed to be hand-in-hand with the shattering of glass. Both are in the same category as Level 1 and usually share control mainframes with sound clocks.

Why do carbon dioxide fire extinguisher pay attention to the risk of asphyxiation?

It reduces the oxygen concentration fire, and significant releases in closed or unventilated space can be frustrated and should be used as soon as possible to leave open.

What is the maintenance of emergency lighting and instructions?

Battery discharge tests, appliances and coverage checks, orientation correctness and whether to be licensed or astronomical. The ageing of batteries is one of the most common deficiencies in annual inspection.

sprinkler head whose replacement is needed at times?

A second level contractor is treated by a collision change, oil-contaminated or painted cover, astronauts or decals, leakage, or when repositioning is required for fitting.

Is it possible to buy the products themselves for re-insertion?

No recommendation may also be inconsistent with legislative requirements. The installation, maintenance, repair or inspection of fire service installations in the premises shall be carried out by a contractor registered at the appropriate level, otherwise it is difficult for an annual inspection to issue FS251 reflecting the validity situation.

Is it necessary to replace the product with FS251?

The contractor shall issue FS251 upon completion of the installation, maintenance, repair or inspection and send a copy to Fire Services Department within 14 days; A full electronic copy of the second-dimensional code has been submitted and generated.

How is the product counted?

Depending on type, specifications, quantity, location of installation and conditions of construction; Replacement of medicines, batteries and sprinkler head is generally based on components, with savings in attendance costs associated with annual inspections. For further detailsProcurement and installation matters。

Can products be purchased only without maintenance contracts?

It is possible. We can supply and install on a separate basis, as well as join regular maintenance and annual inspection as required; A statutory annual inspection and certification may also be delegated independently.

More common issuesLiaison with us

There is a need for fire safety products " , fire extinguisher annual inspection or FS251 annual fire safety inspection?