Dry powder fire extinguisher
The broadest range of hand-held fire extinguisher applies to categories A (wood, paper, plumbing), B (flammable liquid and flammable gases) and C (electric devices) fire, which are the most common types of shop, office, industrial building and vehicles.
Note: More residues of post-spray powder are needed for clean-up; Long-outstanding potential dry powder packs are subject to annual inspection. Special metal fire requires the use of special fire extinguishers, which cannot be assumed to apply in general dry powder.
Category ACategory BCategory CLevel 3

Water agent fire extinguisher
Water-clearing fire extinguisher is used to save wood in combustion, cotton textiles and paper type A fire, often in old buildings and storage sites.
Note: Cables are used to inculcate electrical equipment, flammable liquids or metals in combustion, clean water-up and spread the oil fire.
Category ALevel 3

foam fire extinguisher
Insulated air with foam cover is applicable to categories A and B fire, particularly flammable liquids in combustion, which are often found at work sites involving oil or solvents.
Note: The foam is a guiding body, and it is used to extinguish electrical equipment in combustion.
Category ACategory BLevel 3

carbon dioxide fire extinguisher
(b) Applies electrical equipment in combustion, flammable liquids, sophisticated instruments, important documents or fire occurring in closed areas; The fires will not be residueed and suitable for server room, electrical appliances and the restaurants area.
Note: Carbon dioxide can be an abhorrent, and after fire extinguisher it should go to the open space; Incendiary combustion of deep layers such as paper plumbers is more difficult to completely extinct.
Category BCategory CLevel 3

fire blanket
The isolation of the air by means of coverage is a permanent equipment for food premises and kitchens applicable to flammable liquids in combustion, as well as small fires occurring in kitchens or laboratories.
Note: The use shall be followed by checking whether or not the damage or carbonization; The location should be close to the lithium but not directly polluted by oil smoke.
Application of kitchensLevel 3

exit sign
Fixed-launching plates that direct an approved export route, the maintenance of a backup battery at the time of the suspension, are the most basic guiding devices for moving the flame.
Keys for maintenance: whether the direction is correct, whether it has been branded, astronomical or dressed, and whether the batteries can still be maintained at the prescribed time.
Evacuation instructions

Emergency lighting
Installation is in the building to provide sufficient backup lighting as a matter of urgency, ensuring that fire corridors, stairs and exports continue to be fitted for evacuation in the event of power cuts.
Maintenance keys: periodic discharge testing, battery life, fluid cover and walking of the flame receptacle; The ageing of batteries is one of the most common deficiencies in annual inspection.
emergency lighting

fire safety . / ⁇ system
In the building, the water column can be fired at any time into any part of the building in order to save the fire. fire hose reel was used for early rescue of the person present, while fire safety was provided by fire safety officers to access water.
Keys for maintenance: Water pressure and water testing, plumbing and spraying conditions, the availability of filters, valves and markings, and non-disrupted by impurities. Beneficiary of level 2.
Water fire extinguishingLevel 2

fire Detection System
Systems for automatic detection and alarming of cigarettes, heat, combustion-generated substances or flames, consisting of detectors, control mainframes, sound clocks and back-up power sources, can be linked to winds, gates or gaseous fire suppression system.
Selective elements: corridors and office smoke detector; Heat detector should be used to reduce miscalculations, such as kitchens, car rooms, where it is easy to generate gas or oil smoke. Under level 1 contractor.
Automatic detectionLevel 1

Hand-held fire alarm system
When fire occurs, glass can be broken into the start alarms, other persons within the dispersal site and associated devices (e.g. fire pumps, if any).
(c) Keys for maintenance: whether the position is easy to approach, whether or not the former are blocked by the goods, brake tests and repositions, and whether the marking is clear. Under level 1 contractor.
People ' s hands-onLevel 1

sprinkler system
When fire occurs, sprinkler head feels that designated temperatures will automatically pump water and launch water flush alarms, while local control of the spread of fire is a core firefighting system for large businessfields, industrial building and warehouses.
(c) Maintenance keys: sprinkler head shall not be wheeled, branded, mounted or tubed; The high level of dumping of goods shall not affect the water; Anyone affected by collision or covered by the paint shall be replaced. Beneficiary of level 2.
Water fire extinguishingLevel 2